Four ways to measure the level
Float switch
It switches when the water reaches a set height, which protects the pump from running dry or starts the refill. It does not measure how much water is in the cistern.
Ultrasound
The sensor sits above the highest water level and measures continuously and without contact how long a sound pulse takes to reach the water surface and come back. A temperature sensor makes up for the speed of sound changing with temperature. Directly below the sensor it cannot evaluate anything, and the inflow jet or fittings in the sound cone can disturb the echo.
Pressure probe
A probe in the water measures the pressure of the water column above it, which rises with the level. Foam and fittings do not disturb this hydrostatic measurement. The probe hangs in the water permanently for this, and the air pressure has to be compensated, for example through a tube in the cable.
Radar
Like ultrasound, the sensor measures from above and without contact, with microwaves instead of sound. According to the manufacturer, temperature and pressure do not affect the measurement. Inflow jet and fittings in the beam can disturb it here too, and with plastic tanks also metal parts outside the wall.
From water level to litres
A sensor delivers a height. How many litres belong to it depends on the cistern’s shape. In an upright cylinder every centimetre holds the same amount; in a horizontal tank or a spherical cistern a centimetre in the middle holds more than at the bottom or the top. Measuring devices therefore calculate with a table of height and content. Some have it stored for horizontal cylinders, otherwise you enter value pairs or record them by filling in known amounts.
In addition, only the water above the pump’s intake can be used. One manufacturer gives the example of 300 litres left in a tank of 3,000 litres.
When mains water tops it up
The German rainwater association fbr recommends designing the cistern for a dry period of at least 14 days, on average with 5 to 7 m³ per 100 m² of planted area. If the drought lasts longer, the rainwater runs out just when the garden needs it most. Then an automatic mains water top-up steps in. When the level falls below a switching point, a solenoid valve opens and lets drinking water in.
Drinking water and rainwater stay separate
Water from the cistern is not drinking water. Bird droppings and particles can be washed in from the roof, and it can be contaminated microbially and chemically. If it gets into the drinking water installation, that is a hygiene risk reaching as far as the public network. In Germany the Drinking Water Ordinance therefore only allows a connection between the drinking water installation and the cistern through a protection device according to the generally recognised rules of technology. According to DIN 1988-100, that is an air gap of type AA, AB or AD according to DIN EN 1717 at the connection.
With an air gap, the drinking water pipe ends open above the water. The distance to the highest possible water level is at least twice the diameter of the inlet pipe, no less than 20 mm, and the outlet cannot be flooded. A non-return valve or pipe disconnector is not enough. The air gap often comes in a ready-made refill module. Further requirements are set out in DIN EN 16941-1 and DIN 1989-100, which replaced the former DIN 1989-1 in 2022.
- Ultrasound measures the distance to the water surface
- The pump’s intake
- Remainder below the intake
- Mains water pipe of the refill
- Air gap, at least two pipe diameters and no less than 20 mm above the highest possible water level
- Overflow at the highest possible water level
A cistern in section. Schematic, not to scale.
The protection device is part of the drinking water installation. Under Section 12 of the German AVBWasserV, only the water supplier or an installer listed in a water supplier’s register may build it or change it substantially. According to DIN EN 806-5, such a firm inspects and maintains the air gap every six months. Rainwater taps are permanently marked as not drinking water, and the refill pipe stays short so that water does not stand in it for long. The notification duties that may come with it are summarised in the DVGW leaflet (in German).
Top up only as much as is needed
Every litre of drinking water in the cistern takes up space the next rain would otherwise fill. When the cistern is full, the rain runs off through the overflow. It therefore makes sense to top up only as much as is needed until the next watering. With one manufacturer, each time the float switch switches, about a family’s daily need flows in. Other systems feed into a small tank in the domestic water unit that supplies only the amount needed right now. Then no drinking water gets into the cistern at all.
Protect the pump from running dry
Pumps for rainwater are usually centrifugal pumps, and the water they pump cools and lubricates them. If a centrifugal pump runs dry, it risks overheating, wear and seized parts, according to a pump manufacturer. Dry-run protection switches it off when the water level drops too low. A float switch in the cistern does this, or the pressure switch on the pump, ideally with this function built in.
Overflow and frost
After heavy rain a full cistern overflows. The overflow is best led to a soakaway, otherwise into the sewer, and then with a backflow stop so that no water from the sewer pushes into the cistern. The cistern has to be frost-proof, and its inlet and outlet pipes should usually lie about 80 cm deep. According to the fbr, irrigation pipes lie about 30 cm deep and are drained before the frost.
How Tropfwerk does it
If a cistern is connected, Tropfwerk measures its level continuously by ultrasound and shows it in litres, and a reserve always stays in it. If the water is not enough for the next watering, Tropfwerk tops up with mains water beforehand. The refill reaches the cistern through an air gap according to EN 1717, so no rainwater can flow back into the drinking water pipe. If the level drops too far while watering, Tropfwerk refills and so protects the pump from running dry. The cistern’s curve in the history shows whether rain, refill or withdrawal changed the level. Tropfwerk calculates the need every night from the weather, more on that in the guide on water needs.